Ventilation and Air Conditioning

Supply, extract and air conditioning, drawn as ducts between fans, units, grilles and diffusers. 33 fittings, round and rectangular ducts, and the air through each duct read from the terminals it serves.

Draw the ventilation

Every property, and what it does

Select a duct or a fitting and these are its rows. A band shows when it applies, so a rectangular duct has its aspect and equivalent round size.

The catalogue

The fittings, by the system they are on.

FieldWhat it doesValues
Supply airThe supply air fittings, each with its plan symbol and its usual mounting height.Transfer grille, External louvre, Balancing damper, Volume control damper, Fire damper, Fire and smoke damper, Smoke damper, Relief damper, Humidity sensor, MVHR unit, Inline fan, Centrifugal fan, Duct silencer, Air filter
Extract airThe extract air fittings, each with its plan symbol and its usual mounting height.Extract fan, Backdraft damper
Air conditioningThe air conditioning fittings, each with its plan symbol and its usual mounting height.Supply diffuser, Return grille, Air handler, Supply register, Cooled beam, VAV box, CAV box, Split system, Air conditioning unit, Rooftop unit, Dehumidifier, Chiller, Cooling coil, Humidifier
RefrigerationThe refrigeration fittings, each with its plan symbol and its usual mounting height.Compressor, Condenser, Evaporator

Element

What the selected run or fitting is, and which trade it belongs to.

FieldWhat it doesValues
What it isThe catalogue name of the fitting, or the kind of run.Read from the element
KindThe catalogue entry it was drawn from. Change it to swap the fitting, keeping where it sits.The 33 fittings of the trade
SystemWhat it carries. It decides which trade owns it, its colour and its schedule.Supply air, Extract air, Air conditioning, Refrigeration
TradeThe trade that owns it, read from the system. To move it, change the system.Read from the system
SupplyWhether a fitting that needs a supply is connected to one by a run.Connected, Not connected, Not required

Design

Grilles, diffusers and units are drawn from their own design, so the symbol and the body follow it.

FieldWhat it doesValues
PresetA named design for the fitting. Change anything in it and it reads as modified.The fitting's named designs
Design controlsThe parts of the fitting itself, drawn from its own generator, so its symbol and its 3D body follow.By fitting
What that makes itWhat the design comes to, read only, so the schedule cannot disagree with the fitting.Face, Opening, Free area, Face velocity, Limit, Neck

Air

The air through a duct and how fast it runs.

FieldWhat it doesValues
Equivalent roundOn a rectangular duct, the round size with the same friction.Millimetres, read only
AspectThe long side over the short. Flatter than 4 to 1 is flagged.Read only
Air behind itThe air the terminals this duct reaches ask for, from the plant out.Litres per second, read only
Air through itThe air you type for the duct.Litres per second
Speed, LimitHow fast the air runs, against the limit for a duct in that role, so it does not run noisy.Metres per second, read only

Size

The size of a run, and how the plan draws it.

FieldWhat it doesValues
NominalThe diameter of a round run, or the larger side of a duct.Duct sizes in mm, round or width by height
ShapeRound, or rectangular with a width and a height.Round, Rectangular
Drawn asRuns 75 mm and over are drawn to their width with two lines; smaller ones as a single line.Single line, Double line to width

Where it runs, where it sits

A run has two ends and a level at each; a fitting has a height and a facing.

FieldWhat it doesValues
Start, EndThe fitting each end is bound to. A bound end goes wherever the fitting goes.Read from the plan
Level at start, Level at endHow high each end is above the storey's floor.Millimetres
Invert at start, Invert at endThe level of the inside bottom of the pipe at each end, for runs that fall.Derived from the run it leaves and its gradient
Length in planThe run's length on the plan.Read from the plan
DropHow far the run falls from start to end.Derived from the two levels
HeightHow high a fitting stands above the storey's floor. Negative is below ground.Millimetres; each fitting starts at its usual height
FacingWhich way a fitting faces, anticlockwise from east. 90 faces up the page.Degrees
Flip to the other sideMoves a wall fitting onto the other face of its wall, pointing into the other room.One click

Belongs to

What the schedule files it under, and whether a person has checked it.

FieldWhat it doesValues
CircuitThe circuit or zone the schedule files it under. Where a fitting is wired, the wiring decides.Any name
ProposedMarks what a generator wrote and nobody has checked yet. Confirm clears it.Confirm

How the Ventilation tools work

  1. Open Ventilation

    In the editor, open CAD tools and choose Ventilation. The group has three tools: Catalogue (VENTILATION), Duct (DUCT) and Place (PLACEAIR).

  2. Place the fittings

    Pick a fitting from the catalogue by its system and click where it goes. It stands at its usual height, which its panel can change.

  3. Draw the ducts

    With Duct (DUCT), click each point and press Enter. A run that starts or ends on a fitting snaps to its connection point and is joined to it.

  4. Shape the ducts

    Select a duct to make it rectangular and give its width and height. Its panel shows the air through it and its speed.

Ventilation questions, answered.

What can I place?

MVHR units, inline and centrifugal fans, extract fans, grilles, louvres and diffusers, dampers of every kind, filters and silencers, split systems, air handlers, rooftop units, VAV and CAV boxes, chillers and coils.

Can I draw rectangular ducts?

Yes. Set a duct's shape to rectangular in its panel and give its width and height. It shows the equivalent round size too.

Does it check the ducts?

Yes, as advice: a rectangular duct flatter than 4 to 1, and a duct too small for its air, so the air runs too fast.

Are the services in 3D too?

Yes. Runs are built as real cables, pipes and ducts at their levels, fittings stand at their heights, and a run that crosses a wall or a floor cuts its own hole through it.